M1 classification test report provided | Delivery within 24 working hours | Tel.: +33 1 40 20 02 96

Everything you need to know about the durability of a fire-retardant treatment and its M1 classification

9 April 2026

How long an M1 classification holds depends on the substrate. On solid wood, textiles and artificial foliage it is not limited in time indoors, sheltered from the weather and within the conditions of the test report. The test report itself has its own period of validity, stated at the top of the document: five years for EUROFLOR’s. Over time, it is the condition of the treated substrate that needs watching.

Durability of an M1 fire-retardant treatment: what the report states, and what ends it

The question of how long a fire-retardant treatment lasts often arises when a material has already been treated and is still in use in a public building, an exhibition stand, a hall, an exhibition space or an interior fit-out. A substrate may have been properly treated initially, but may change over time through use, moisture, friction or simply natural ageing.

The durability of a classification is not a matter of opinion: it is a line in the classification report, and it differs from product to product. For EUROTEXTIL, EUROFLOR and EUROMASSIF BOIS, the report states it as not limited in time, for materials used sheltered from the weather — and, for textiles and artificial foliage, on an item that is neither washed nor dry-cleaned. So the honest answer to “how long does it last?” begins by asking which product was used, and reading the line in that product’s own report.

Key points

  • What ends a classification is leaving the conditions of the report, not the passing of time. Water, washing, dry cleaning, abrasion and outdoor exposure all fall outside those conditions.
  • Applying the quantity the report states is what makes the classification the one that was established. Under-applying does not give a weaker class — it gives none.
  • Look the installation over every 2 to 3 years, and more often in areas subject to wear or frequent handling. That is upkeep of the item, not an expiry of the class.
  • Two documents are kept on file, and they are distinct: the classification test report of the product, and the application declaration completed and signed by the company that applied it.
  • A substrate that has been washed, coated over or materially altered is outside the report. Re-treating it is the way back in.

Why does a treated material change over time?

Fire-retardant treatments work by changing how the treated material reacts to fire — in most cases by impregnating the fibres, or by forming a film on the surface. As long as the active agents stay in place, and the material stays in the condition the report describes, the classification established by that report applies to it.

What changes that is not the calendar. It is anything that takes the material out of those conditions: water, washing, dry cleaning, repeated friction and abrasion, a coating applied on top, or exposure to the weather. Dust and handling matter too, but mainly because they make the surface harder to assess.

This is why the useful question is not “has the treatment expired?” but “is this material still in the state the report describes?”

The two documents, and what each one establishes

Two documents travel with a treated material. They are often confused, and they do different things.

The classification test report

Issued by an accredited laboratory — the LNE for our ranges. It establishes the class, on a stated substrate, applied a stated way, at a stated quantity, and it states the durability of that class. It is the document the class rests on. It is not ours to amend, and it says what it says: where your substrate is not in it, no class is established for your substrate.

The application declaration

Supplied blank with the order and completed and signed by the company that carried out the treatment. It records what was actually done: the substrates treated, the areas, the product references and quantities, and the weighings before and after where they apply. It establishes no class of its own — it ties a real job to the report that classifies the product used.

Neither document removes the need to look at the material. Together they say what was classified and what was applied; the condition of the surface today is a separate question, and it is the one the rest of this page is about.

What takes a material outside the report

Factor What it does Effect on the classification
Water, washing Leaches the active agents out of the fibre Outside the report. For textiles and foliage the report says in as many words: neither washed nor dry-cleaned
Dry cleaning Not covered by the test conditions Outside the report, on the same line as washing
Outdoor exposure Weather, run-off, UV Outside the report. Our wood and textile classifications are given for materials kept sheltered from the weather
Abrasion, friction Wears the treated surface or the film Worth checking, and worth re-treating where the surface is visibly worn
A coating applied on top Changes the configuration that was tested Outside the report. Never paint or varnish over an impregnation
Under-application at the outset Less active agent than the tested quantity No class was established in the first place — this is not a durability question
Dust and grime Accumulates on the surface Does not itself end the class. For a treated textile, the report’s own ageing test ends with the specimens being brushed with a nylon brush, so dusting with a soft brush is covered

For textile substrates, see our range of products for fabrics.

The quantity applied, product by product

The durability of a class does not depend only on what happens to the material afterwards. It depends first on whether the class was ever established — and that turns on the quantity applied. Under-application is not always visible, and it does not produce a lesser class: it produces none.

The quantities below are each from the report of the product concerned. They are not interchangeable:

  • EUROMASSIF BOIS, wood impregnation by immersion: 5.5 kg/m² wet at saturation on removal from the bath — about 0.18 m² treated per litre absorbed. Immersion is the only method the report validates.
  • VI BOIS, intumescent varnish: 200 g/m² wet, which is 170 µm wet — about 6 m² per litre.
  • EUROTEXTIL and EUROFLOR, textiles and artificial foliage: applied by spraying or soaking until the substrate is saturated and the excess runs off, in a single application. The volume needed therefore follows the weight of the substrate rather than a fixed figure per m².

A caution worth stating plainly: 6 m² per litre is the varnish figure. Applying it to a wood impregnation would under-dose by more than an order of magnitude. Each product has one quantity, in its own report, and in its own unit.

For wooden substrates, see our fire-retardant solutions for wood.

How to check a surface that has already been treated

What can be checked on site is the state of the material — not its class. The distinction matters, so it is worth being explicit about it.

A sensible rhythm is a look every 2 to 3 years, and more often on anything that gets handled, brushed past or cleaned regularly. To be clear about why: the class itself does not run out on a date — for our textile, foliage and wood impregnation the report gives it as not limited in time. What a periodic look is for is the item: to catch the things that take it outside the report, and to notice when a material has quietly been replaced, re-covered or moved.

  • Look for what takes it outside the report: signs of washing or water, a coating applied over the treatment, visible abrasion in high-traffic areas, corners and handled edges, and any move to an outdoor or exposed position.
  • Check the file against the installation: that the classification report covers the substrate actually in place, and that the application declaration describes the areas actually treated. A mismatch here is the most common problem at an inspection, and it is found on paper, not on the wall.
  • Keep a record: the date of treatment, the product used, the areas treated and the checks carried out. It takes a line, and it is what makes the file hold together over years.

What not to do: do not hold a flame to the material or to a sample of it. A reaction-to-fire class is established by standardised tests in an accredited laboratory — for the M classes, by the NF P 92-501 series and the classification standard NF P 92-507. A flame held to an offcut tells you nothing about M1: the test fixes the specimen, the ignition source, its position, its duration and what is measured, and none of that can be reproduced by hand. It is also a fire risk and it damages the material. Where there is a real doubt about a class, the answer is a dedicated test — not an improvised one.

Where you need certainty rather than reassurance, get in touch: we will look at what the report covers and, if necessary, arrange a test.

Which substrates need the most attention

Substrate What the report says What to watch
Interior wood, impregnated Durability not limited, sheltered from the weather Wear, surface changes, moisture — and above all any coating applied on top
Decorative textiles and artificial foliage Durability not limited, sheltered from the weather, on an item neither washed nor dry-cleaned Washing and dry cleaning both end it. Dusting with a soft brush is covered; cleaning with water is not
Cardboard (EUROCARTON) No classification stated for cardboard The EUROCARTON range is currently out of stock. For a cardboard project, ask us and we will tell you what we can do.
Paper, natural plants Covered by none of our reports We claim no classification on them, and we give no dosage for them. Ask us and we will assess feasibility
High-traffic areas, whatever the substrate — Abrasion, impact, frequent cleaning

Keeping a treated material within the report’s conditions

  • Keep treated materials sheltered from the weather, and away from water.
  • Do not wash or dry-clean a treated textile or treated foliage. Dust it with a soft brush.
  • Do not paint, varnish or otherwise coat over an impregnation: that is a different configuration from the one that was tested.
  • Check high-traffic areas, corners and frequently handled parts.
  • Put the look-over on a cycle — every 2 to 3 years for an ordinary installation — so it happens before an inspection rather than because of one.
  • Keep the written record of applications, touch-ups and checks — and keep the classification report and the signed application declaration with it.

If your project calls for treatment at scale, see the treatment service we run in our own workshops.

When to re-treat

Re-treating is the way to bring a material back within the conditions of the report. It is worth considering where the substrate has been washed or has taken water, where it shows visible wear or has been materially altered, where it has been coated over, or where it has been moved to a position the report does not cover.

It is also worth a look when a material has been in storage a long time, moved repeatedly, or brought back into service after a long period without inspection — not because the class lapses on its own, but because what has happened to it in the meantime is usually unknown.

For wooden surfaces, it may be worth comparing fire-retardant impregnation and intumescent varnish, since they do not cover the same substrates.

In summary

The durability of a classification is a line in a classification report, and it differs by product: for our textile, foliage and wood impregnation it is not limited in time, for materials sheltered from the weather and on items neither washed nor dry-cleaned. What ends a class is leaving the conditions of the report — washing, dry cleaning, weather, a coating applied over it — rather than the passing of time.

Keeping a treated material in order therefore rests on four things: applying the quantity the report states, keeping the material in the conditions it describes, keeping the report and the signed application declaration together, and looking at the surfaces from time to time — every 2 to 3 years is a reasonable interval. Where there is a genuine doubt about a class, the answer is a test in a laboratory — and we will tell you so rather than let you improvise one.