{"id":24832,"date":"2021-12-07T14:55:54","date_gmt":"2021-12-07T13:55:54","guid":{"rendered":"https:\/\/www.alfaflor.com\/erp-fire-standards-in-which-cases-should-fireproofing-be-used\/"},"modified":"2026-11-20T18:06:50","modified_gmt":"2026-11-20T17:06:50","slug":"erp-fire-standards-in-which-cases-should-fireproofing-be-used","status":"publish","type":"post","link":"https:\/\/www.alfaflor.com\/en\/erp-fire-standards-in-which-cases-should-fireproofing-be-used\/","title":{"rendered":"PAB fire standards : in which cases should fire-retardant treatment be used in France?"},"content":{"rendered":"<p>PAB fire standards in France are very strict for obvious reasons. Indeed, Public Access Buildings are subject to the <a href=\"https:\/\/www.legifrance.gouv.fr\/loda\/id\/LEGITEXT000020397555\" target=\"_blank\" rel=\"noreferrer noopener\">arr\u00eat\u00e9 of 21 November 2002<\/a> to prevent fires. That regulation sets a reaction-to-fire class for each category of fit-out through its AM articles, and the class required depends on the activity and the capacity of the establishment: it does not require non-combustible furniture throughout. This is why PAB suppliers and PAB operators must check which class applies to each element, and whether the materials reach the <a href=\"https:\/\/www.alfaflor.com\/en\/treatment-anti-fire-standard-m1-m2-m3-etc-classification-for-eop\/\" target=\"_blank\" rel=\"noreferrer noopener\">M1 classification<\/a> where it is the one required. It is possible to purchase materials or furniture that are already classified M1. But in other cases, the material must be treated. Let\u2019s look at some examples where an M1 classification is the one at stake :<\/p>\n<h2>Curtain fire-retardant treatment and theater decor<\/h2>\n<p>Theater sets and curtains are among the fit-out elements for which the AM articles set a reaction-to-fire class; the class required for your venue is stated by your inspection office for the project. It is possible to buy a curtain that is already fire-retardant or to then treat it with our product <a href=\"https:\/\/www.alfaflor.com\/en\/boutique\/fire-retardants\/textile-flame-retardants\/fire-retardant-textile-eurotextil\/\" target=\"_blank\" rel=\"noreferrer noopener\">Eurotextil<\/a>, whose M1 classification was established on \u00ab polypropyl\u00e8ne 70 g\/m\u00b2, polyester 175 g\/m\u00b2, lin 230 g\/m\u00b2 et coton 150 g\/m\u00b2 \u00bb (translation: polypropylene 70 g\/m\u00b2, polyester 175 g\/m\u00b2, linen 230 g\/m\u00b2 and cotton 150 g\/m\u00b2). You can make a wooden set and need to treat it before putting it on stage. In this case, we advise you to use <a href=\"https:\/\/www.alfaflor.com\/en\/boutique\/fire-retardants\/wood-fire-retardants\/fire-retardant-for-wood-euromassif-bois\/\" target=\"_blank\" rel=\"noreferrer noopener\">EUROMASSIF BOIS<\/a>, whose classification was established on \u00ab sapin jaune, 10 mm d&#8217;\u00e9paisseur, par trempage jusqu&#8217;\u00e0 saturation \u00bb \u2014 in English, <strong>Yellow Pine<\/strong>, 10 mm thick, by dipping until saturation. The French wording of the classification report prevails.<\/p>\n<h2>Fire-retardant treatment of decorations in shopping centers and department stores<\/h2>\n<p>Installing an artificial green wall, a Christmas tree, or an artificial flower decor is not trivial in an ERP. The decor will be checked by the control office of the store in which it will be displayed. Landscaper, decorator, you must provide your client with the file for each element you have treated. A composite decor is not classified as an object: the classification follows the material. For an artificial green wall, the classification established for Euroflor covers the treated fibre foliage; the structure of the wall, the moss and the moulded stems do not fall under it. For a decor with flowers or artificial plants, use <a href=\"https:\/\/www.alfaflor.com\/en\/boutique\/fire-retardants\/artificial-plants-fire-retardants\/flame-retardant-artificial-plants-euroflor\/\" target=\"_blank\" rel=\"noreferrer noopener\">Euroflor<\/a> \u2014 article AM 19 \u00a7 6 sets M2 for artificial floral decorations. If fabric is part of the scenography, it can be treated with Eurotextil, within the supports listed above. For a wooden decor, EUROMASSIF BOIS applies within the species, thickness and dipping protocol of its own report; outside them, no classification is established and the file is assessed with the inspection office.<\/p>\n<h2>Fire-retardant treatment of stand furniture for an event show<\/h2>\n<p>Are you exhibiting at a fair or event show? You must be able to prove the reaction-to-fire class of the stand elements with a classification test report. Two categories are outside what our textile report establishes: our test report carries the mention \u00ab VALABLE POUR TOUTE APPLICATION NON COUVERTE PAR L&#8217;ART. AM18 \u00a72 DE LA REGLEMENTATION ERP \u00bb (translation: valid for any application not covered by art. AM18 \u00a72 of the ERP regulation), and that article covers both seats and floor coverings. We therefore claim no class on a treated carpet or on upholstered seating, and you should treat an offer to do so with suspicion.<\/p>\n<p>Do you want to treat your materials to meet the requirements that apply to your project? Do not hesitate to <a href=\"https:\/\/www.alfaflor.com\/en\/\" target=\"_blank\" rel=\"noreferrer noopener\">contact us<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>PAB fire standards in France are very strict for obvious reasons. Indeed, Public Access Buildings are subject to the arr\u00eat\u00e9 of 21 November 2002 to prevent fires. That regulation sets a reaction-to-fire class for each category of fit-out through its AM articles, and the class required depends on the activity and the capacity of the [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":24660,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rank_math_title":"When is fire-retardant treatment required in public venues? | Alfaflor","rank_math_description":"The quickest solution to meet fire safety standards for ERP ? Fire-retardant treatment by spraying. Find out when to use it.  ","rank_math_focus_keyword":"ERP fire safety standards","rank_math_canonical_url":"","rank_math_robots":["index"],"footnotes":""},"categories":[190],"tags":[],"class_list":["post-24832","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standards-and-regulations"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/posts\/24832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/comments?post=24832"}],"version-history":[{"count":11,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/posts\/24832\/revisions"}],"predecessor-version":[{"id":32344,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/posts\/24832\/revisions\/32344"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/media\/24660"}],"wp:attachment":[{"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/media?parent=24832"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/categories?post=24832"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.alfaflor.com\/en\/wp-json\/wp\/v2\/tags?post=24832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}